Difference between revisions of "Remove A1"
(→Klipper firmware compilation) |
(→Entering boot-mode after flashing) |
||
(2 intermediate revisions by the same user not shown) | |||
Line 67: | Line 67: | ||
After that, the board should be visible as OpenMoko, Inc. rp2040 | After that, the board should be visible as OpenMoko, Inc. rp2040 | ||
<div class="res-img"> | <div class="res-img"> | ||
− | [[File:Screenshot from 2024-09-04 18-41-48.png | + | [[File:Screenshot from 2024-09-04 18-41-48.png]] |
</div> | </div> | ||
Line 73: | Line 73: | ||
If a firmware upgrade is necessary, the device must be put into boot mode. This can be done by short together the test points shown below while inserting the USB port. | If a firmware upgrade is necessary, the device must be put into boot mode. This can be done by short together the test points shown below while inserting the USB port. | ||
[[File:Remove pinout back.png|center]] | [[File:Remove pinout back.png|center]] | ||
+ | |||
+ | Or alternatively, you can enter the boot-mode by requesting a baud rate of 1200 | ||
+ | <pre> | ||
+ | picocom -b 1200 <DEVICE> | ||
+ | </pre> | ||
+ | More info here: [https://www.klipper3d.org/Bootloader_Entry.html] |
Latest revision as of 23:35, 18 November 2024
Remove is an accelerometer for doing input shaping with Klipper.
Contents
Pinout diagram
Klipper configuration
# The Remove resonance tester mcu [mcu rp2040] serial: /dev/ttyACM0 baud: 1500000 [adxl345] cs_pin: rp2040:gpio5 spi_bus: spi0a [resonance_tester] accel_chip: adxl345 probe_points: 100, 100, 20 # an example [static_digital_output remove_leds] pins: rp2040:gpio17, rp2040:gpio18
Klipper usage
To test the accellerometer, try this in the user interface:
ACCELEROMETER_QUERY
At this time there is an issue with the A1 board where the initialization can fail in Klipper.
If you follow the klipper documentation and run the expected commands you may get the following error:
Invalid adxl345 id (got f2 vs e5). This is generally indicative of connection problems (e.g. faulty wiring) or a faulty adxl345 chip.
This does not mean your Remove is faulty. Try running the command again, it is a known initialization error, and will go away once the initial message happens. It will happen again next time you restart klipper though, as it re-initializes the ADXL345 again.
After that first test, the actual calibration can be run with:
TEST_RESONANCES axis=x
Read more on the Klipper pages: [1]
Klipper firmware compilation
The unit comes with firmware pre-installed. If you want to upgrade the firmware, these are the steps to reproduce. This can be done directly from Recore, or from a regular computer. If the device ID doesn't match, the board is not in DFU mode, and needs to be manually started that way. Use a paperclip or some wire, unplug the USB of the device, short the two round pads on the back of the PCB and plug in the USB. At that point the RP2040 will be in DFU mode, allowing it to be flashed.
cd /home/debian/klipper cp test/configs/rp2040.config .config make olddefconfig make -j make flash FLASH_DEVICE="2e8a:0003"
After that, the board should be visible as OpenMoko, Inc. rp2040
Entering boot-mode after flashing
If a firmware upgrade is necessary, the device must be put into boot mode. This can be done by short together the test points shown below while inserting the USB port.
Or alternatively, you can enter the boot-mode by requesting a baud rate of 1200
picocom -b 1200 <DEVICE>
More info here: [2]