Difference between revisions of "Recans A0"

From iagent
Jump to: navigation, search
Line 23: Line 23:
  
  
Errata:
+
===Errata===
 
- SPI_CLK and SPI_MOSI are interchanged and need to be fixed.  
 
- SPI_CLK and SPI_MOSI are interchanged and need to be fixed.  
 
- /RESET is floating.
 
- /RESET is floating.

Revision as of 23:06, 21 February 2024

Recans A0 has two controllers, one is based on RP2040, the other on MCP2515.

To bring up the RP2040 CAN controller:

sudo ip link set can0 type can bitrate 1000000
sudo ip link set up can0

The MCP2515 CAN controller

sudo mount -o remount,rw /boot
sudo armbian-add-overlay /boot/overlay-user/sun50i-a64-spi1.dts
sudo mount -o remount,ro /boot
ls -al /dev/spidev1.0

Interrupt: STEP7 = PL11


Errata

- SPI_CLK and SPI_MOSI are interchanged and need to be fixed. - /RESET is floating.