Recans A0
From iagent
Recans A0 has two controllers, one is based on RP2040, the other on MCP2515.
To bring up the RP2040 CAN controller:
sudo ip link set can0 type can bitrate 1000000 sudo ip link set up can0 sudo ifconfig can0 txqueuelen 128
The MCP2515 CAN controller
sudo mount -o remount,rw /boot sudo armbian-add-overlay /boot/overlay-user/sun50i-a64-mcp251x.dts sudo mount -o remount,ro /boot
After booting:
dmesg | grep mcp
sudo ip link set can1 type can bitrate 1000000 sudo ip link set up can1 sudo ifconfig can1 txqueuelen 128
Interrupt: STEP7 = PL11
sudo apt install net-tools can-utils
cansend can1 5A1#11.2233.44556677.88
ip -details link show can0
~/klippy-env/bin/python ~/klipper/scripts/canbus_query.py can0
Errata
- SPI_CLK and SPI_MOSI are interchanged and need to be fixed.
- /RESET is floating.
Debug
During init/reset:
TX: 0x03 0x0E 0x00 = READ CANSTAT RX: 0x00 0x00 0x80 = Device is in Configuration mode
When trying to set interface up:
TX: 0x02 0x0F 0x80 = WRITE CANCTRL REQOP2 RX: 0x00 0x00 0x00
TX: 0x03 0x0E 0x00 = READ CANSTAT RX: 0x00 0x00 0x64 = OPMOD[2:0] = 0b011, ICOD[2:0] = 0b010
Device is in Listen-Only mode, Wake-up interrupt